NU Labs is accredited by A2LA to ISO/IEC 17025:2005
General Requirements for the Competence of Testing and Calibration
Laboratories for MIL-STD-461 and Power Quality Testing
Click logo for scope of accreditation

Testing Laboratory
Cert #3122.01
NU Labs is equipped with two
shielded enclosures to provide electromagnetic
interference testing required by current Military specifications. The first
is a Panashield semi-anechoic electromagnetic shielded enclosure. It
has an inside dimension of 23' x 16' x 12' with a usable test area of 9.8' x
8'. The chamber uses 20" carbon impregnated cone material for RF
absorption and conforms to MIL-STD461E/F.
The second chamber, a Universal
Shielding Corp. shielded enclosure, measures 12' x 9' x 9' and has a entry
door that is 35.5" wide by 84" high. All power to both chamber is
filtered.
We provide testing and engineering
services from full engineering evaluation to full qualification tests. NU
Laboratories can aid in troubleshooting as well as provide solution
engineering for EMI/EMC problems and test failures.

EMC Capabilities
DC through 480V ac up to 100 AMPS
LISN up to 800V dc and 500V ac, up to 200 AMPS
Over 20 V/m 10kHz to 18GHz
Special Utilities and Large Test Unit Capabilities:
Double wide chamber door, 72" wide by 89"
tall for large EUT's
Forklift with 5000 lb pallet load
In house welding
Custom built fixtures
Waveguide feed through for hydraulic and pneumatic lines
Cooling water, 100 psig, 3/4" hose fittings
Compressed air, 100 psi
NU Labs is A2LA accredited and can perform
accredited testing to the following standards:
MIL-STD-461C, D, E and F, Electromagnetic Compatibility
MIL-STD1399 Sec. 300A, and 300B, Interface Standard for Shipboard Systems
DOD-STD-1300 sec.070, DC Magnetic Field Environment

In addition, NU Labs can also perform testing to:
MIL-STD-285, Attenuation Measurements for Shielded Enclosures
IEC 6100-4-2, Electro Static Discharge (ESD) up to 20 kV
RCTA\DO-160 D/E
Chamber and test equipment are also available
for use on an hourly/daily basis for research and development
Magnetic Loop
Inside diameter: 66 inches
Outside diameter: 77 inches
Inside width: 3 inches